Electrical data |
---|
Operating voltage [V] | 10...30 DC; ("supply class 2" to cULus) |
Current consumption [mA] | 55 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 0.3 |
Converter frequency [kHz] | 200 |
Inputs / outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Electrical design | PNP |
Number of digital outputs | 1 |
Output function | normally open / normally closed; (parameterisable) |
Max. voltage drop switching output DC [V] | 2.2 |
Permanent current rating of switching output DC [mA] | 100 |
Switching frequency DC [Hz] | 2 |
Number of analogue outputs | 1 |
Analogue current output [mA] | 4...20 |
Max. load [Ω] | 500 |
Short-circuit protection | yes |
Overload protection | yes |
Resolution of analogue output | < 3 mm |
Detection zone |
---|
Sensing range [mm] | 200...2200 |
Blind zone [mm] | 200 |
Angle of aperture cylindrical [°] | 8; (±2) |
Detection range hysteresis [mm] | < 1 |
Max. deviation from the 90° angle sensor/object [°] | ± 4 |
Accuracy / deviations |
---|
Notes on the accuracy / deviation | The indicated values are reached after a warm-up time of min. 20 minutes |
Temperature compensation | yes |
Hysteresis [%] | 1 |
Switch point drift [%] | -2...2 |
Linearity error of analogue output [%] | 1 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission type | COM2 (38,4 kBaud) |
IO-Link revision | 1.1 |
SDCI standard | IEC 61131-9 |
Profiles | Smart Sensor: Process Data Variable; Device Identification |
SIO mode | yes |
Required master port type | A |
Min. process cycle time [ms] | 3.2 |
Operating conditions |
---|
Ambient temperature [°C] | -20...70 |
Protection | IP 67 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / plastics | | 8 kV AD / metal | EN 61000-4-3 HF radiated | 3 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-6 HF conducted | 3 V | EN 55011 | Class A |
|
Vibration resistance | EN 60068-2-6 Fc | (10-55) Hz 1 mm amplitude, oscillation period 5 min., 30 min. per axis at resonance or 55 Hz |
|
Shock resistance | |
MTTF [years] | 142 |
Mechanical data |
---|
Weight [g] | 102 |
Housing | threaded type |
Dimensions [mm] | M18 x 1 / L = 97.5 |
Thread designation | M18 x 1 |
Materials | stainless steel (1.4404 / 316L); PA; epoxy glass ceramics |
Displays / operating elements |
---|
Display | switching status | 2 LED, yellow | echo | 1 LED, green |
|
Accessories |
---|
Accessories (supplied) | lock nuts: 2, stainless steel |
|
Remarks |
---|
Remarks | operating voltage "supply class 2" according to cULus |
|
Pack quantity | 1 pcs. |
Electrical connection |
---|
Connection | Connector: 1 x M12 |
Diagrams and graphs |
---|
|
1: | distance |
---|
2: | Detection zone |
---|
3: | switch-on/switch-off graph |
---|
4: | Target 200 x 200 mm |
---|
5: | 50 % of the target in the detection zone |
---|
6: | switch point |
---|
|
---|