Electrical data |
---|
Operating voltage [V] | 10...36 DC |
Current consumption [mA] | 15; (24 V) |
Protection class | II |
Reverse polarity protection | yes |
Outputs |
---|
Electrical design | PNP |
Output function | complementary |
Max. voltage drop switching output DC [V] | 2.5 |
Max. leakage current [mA] | 0.5 |
Permanent current rating of switching output DC [mA] | 250 |
Switching frequency DC [Hz] | 300 |
Short-circuit protection | yes |
Type of short-circuit protection | pulsed |
Overload protection | yes |
Detection zone |
---|
Sensing range [mm] | 10 |
Real sensing range Sr [mm] | 10 ± 10 % |
Operating distance [mm] | 0...8.1 |
Accuracy / deviations |
---|
Correction factor | steel: 1 / stainless steel: 0.7 / brass: 0.4 / aluminium: 0.3 / copper: 0.2 |
Hysteresis [% of Sr] | 3...15 |
Switch point drift [% of Sr] | -10...10 |
Operating conditions |
---|
Ambient temperature [°C] | -25...80 |
Protection | IP 67 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 HF radiated | 3 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-5 Surge | 0,5 kV line to line, Ri: 2 Ohm | EN 61000-4-6 HF conducted | 3 V | EN 55011 emission | class B |
|
MTTF [years] | 1447 |
Mechanical data |
---|
Weight [g] | 41.6 |
Housing | threaded type |
Mounting | non-flush mountable |
Dimensions [mm] | M18 x 1 / L = 45 |
Thread designation | M18 x 1 |
Materials | stainless steel (1.4571/316Ti ); sensing face: PBT |
Displays / operating elements |
---|
Display | switching status | 4 x 90° LED, red |
|
Accessories |
---|
Accessories (supplied) | |
Remarks |
---|
Pack quantity | 1 pcs. |
Electrical connection - plug |
---|
Connection | Connector: 1 x M12; Contacts: gold-plated |